Slit lamp VX75 – Visionix

Our large range of column slit lamps garantees you perfectly safe use thanks to a reliable lighting technique and optics.

    Please leave us your contact details and we will come back to you promptly to schedule a remote demonstration. You will need a computer with an internet access, ideally equipped with a webcam and a mic (or a separate phone to liaise the audio).

    Category: Non classé Tags: Diagnostic, Refraction, Slit lamps, Visionix
    • Key benefits
    •  Documentation
    •  Cleaning guidelines

    Description

    Dimensions

    W296 x D313 x H433±15mm
    W11.65 x D12.32 x H17.04±15mm

    Weight

    Lamp 7.4 Kg  (15.43 lbs)–  Digital lamp 8.1 Kg (17.63 lbs)

    Magnifications
    3x/5x
    Parallel version
    •
    Convergent version
    •
    Height adjustment: manual version
    •
    Height adjustment: motorized version
    –
    Slit width
    0 – 14 mm Continually
    Slit length
    1.8 – 13mm Continually
    Slit apertures
    14; 9; 5.5; 0.3mm
    Tyndall point
    Ø 0.3 mm
    Slit rotation
    ± 90° Continually on TABO scheme
    Working distance
    68 mm
    Average viewing height
    375 mm
    Light
    LED
    Max light intensity
    350,000 Lux
    Adjustment
    Longitudinal (In/Out)
    113 mm
    Lateral (Left/Right)
    107 mm
    Vertical (Up/Down)
    30 mm
    Chin-rest height
    76 ±1 mm
    Microscope
    Stereo angle
    6°
    Eyepiece 12.5x
    Total magnification/field of view
    (in mm) for 2 magnifications
    –
    Total magnification/field of view
    (in mm) for 3 magnifications
    10x/24; 16x/14; 25x/8 mm
    Total magnification/field of view
    (in mm) for 5 magnifications
    6x/37; 10x/24; 16x/14; 25x/8; 40x/5.2 mm
    Pupillary adjustment
    48.5 – 80 mm
    Diopter adjustment
    +/- 6D
    Filters
    Blue (fluorescence)
    •
    Green (red-free)
    •
    Grey (anti-heat)
    •
    Yellow
    •
    Electric features
    Power supply
    8475-8001-00
    Power supply for the slit lamp
    ~12V AC;
    Power supply for the fixation point
    12V
    Input voltage
    100V/120V/230V/240V AC; 60/50Hz
    Fuse 100-120V AC — 1A
    230-240V AC — 0.5A
    MDD, CE •
    Safety class
    I
    Parts applied
    Type B
    Tonometer
    8475-8000-00
    Tonometer support plate
    8475-8002-00
    Compatibility with EyePix2
    –
    Compatibility with EyePix3
    •

    Documentation

    Documentation-slitlamps visionix EN

    Cleaning guidelines

    Product desinfected

    FC001158-instructions-cleaning-sterilization-slit-lamps-1FC001158-instructions-cleaning-sterilization-slit-lamps-2

    PreviousNext

    Related Products

    • accessoire cache oeil 7190039 refraction luneau

      White plastic occluder with plain handle

      Add to quote Show Details
    • accessoire-visiere-1197050-opticien-briot

      Removable visor for edging chamber

      Add to quote Show Details
    • Outil calage monture

      Shape Creator Tool

      Add to quote Show Details
    • accessoire-gabarit-1404185-opticien-briot

      Scan alignment adjustment pattern

      Add to quote Show Details

    Contact

    Luneau Technology Operations

    2 rue Roger Bonnet

    27340 Pont-de-l'Arche - France

    picto-phone

    +33 2 32 98 91 32



      The law protects you. Luneau Technology Group accompanies you and respects your choice. You can oppose the use of your data for business development at any time.


      > Privacy policy


      Newsletter

      *Mandatory fields
      Your account
      Sign in/Sign out

       

       

       

      facebook Luneautechnology

       

      Linkedin Luneautechnology

       

      Linkedin Luneautechnology UK Ireland

      Youtube Luneau Technology

      Copyright 2020 Privacy policy | Luneau Technology Group
      • Diagnostic
        • Anterior segment
        • Binocular aberrometry
        • Diagnostic units
        • Fundus camera
        • Slit lamps
        • Tonometer
        • Topographer
      • Refraction
        • ARK
        • Binocular aberrometry
        • Chart Displays
        • Lens detection and analysis
        • Phoropter
        • Pupillometer
        • Refraction units
        • Screening
        • Slit lamps
      • Accessories
        • Color vision
        • Ophthalmoscopy
        • Orthoptics
        • Perimetry
        • Prisms
        • Skiascopy & retinometry
        • Stereoscopy
        • Tonometry
        • Trial lenses sets & frames
      • Disinfection-protection
      Luneau Technology Group
        0 items
      Remote Demo
      PDF Documentation
      Information
      We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok